    High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    Get PDF
    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM)

    A segmented Hybrid Photon Detector with integrated auto-triggering front-end electronics for a PET scanner

    Get PDF
    We describe the design, fabrication and test results of a segmented Hybrid Photon Detector with integrated auto-triggering front-end electronics. Both the photodetector and its VLSI readout electronics are custom designed and have been tailored to the requirements of a recently proposed novel geometrical concept of a Positron Emission Tomograph. Emphasis is put on the PET specific features of the device. The detector has been fabricated in the photocathode facility at CERN

    Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors

    Full text link
    A very high resolution positron emission tomography (PET) scanner for small animal imaging based on the idea of inserting a ring of high-granularity solid-state detectors into a conventional PET scanner is under investigation. A particularly interesting configuration of this concept, which takes the form of a degenerate Compton camera, is shown capable of providing sub-millimeter resolution with good sensitivity. We present a Compton PET system and estimate its performance using a proof-of-concept prototype. A prototype single-slice imaging instrument was constructed with two silicon detectors 1 mm thick, each having 512 1.4 mm × 1.4 mm pads arranged in a 32 × 16 array. The silicon detectors were located edgewise on opposite sides and flanked by two non-position sensitive BGO detectors. The scanner performance was measured for its sensitivity, energy, timing, spatial resolution and resolution uniformity. Using the experimental scanner, energy resolution for the silicon detectors is 1%. However, system energy resolution is dominated by the 23% FWHM BGO resolution. Timing resolution for silicon is 82.1 ns FWHM due to time-walk in trigger devices. Using the scattered photons, time resolution between the BGO detectors is 19.4 ns FWHM. Image resolution of 980 µm FWHM at the center of the field-of-view (FOV) is obtained from a 1D profile of a 0.254 mm diameter 18F line source image reconstructed using the conventional 2D filtered back-projection (FBP). The 0.4 mm gap between two line sources is resolved in the image reconstructed with both FBP and the maximum likelihood expectation maximization (ML-EM) algorithm. The experimental instrument demonstrates sub-millimeter resolution. A prototype having sensitivity high enough for initial small animal images can be used for in vivo studies of small animal models of metabolism, molecular mechanism and the development of new radiotracers.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/58094/2/pmb7_10_012.pd

    Performance of a 128 channel analogue front-end chip for read-out of Si strip detector modules for LHC experiments

    Get PDF
    We present a 128-channel analogue front-end chip, SCT128A-HC, for readout of silicon strip detectors employed in the inner tracking detectors of the LHC experiment. The chip is produced in the radiation hard DMILL technology. The architecture of the chip and critical design issues are discussed. The performance of the chip has been evaluated in details in the test bench and is presented in the paper. The chip is used to read out prototype analogue modules compatible in size, functionality and performance with the ATLAS SCT base line modules. Several full size detector modules equipped with SCT128A-HC chips has been built and tested successfully in the lab with beta particles as well as in the test beam. The results concerning the signal-to-noise ratio, noise occupancy, efficiency and spatial resolution are presented. The radiation hardness issues are discussed. (5 refs)

    Analogue read-out chip for Si strip detector modules for LHC experiments

    Get PDF
    We present a 128-channel analogue front-end chip SCTA128 for readout of silicon strip detectors employed in the inner tracking detectors of LHC experiments. The architecture of the chip and critical design issues are discussed. The performance of the chip has been evaluated in detail in bench tests and is presented in the paper. The chip is used to read out prototype analogue modules compatible in size, functionality and performance with the ATLAS SCT base line modules. Several full size detector modules equipped with SCTA128 chips have been built and tested successfully in the lab with E particles as well as in beam tests

    LHC1: a semiconductor pixel detector readout chip with internal, tunable delay providing a binary pattern of selected events

    Get PDF
    The Omega3/LHCl pixel detector readout chip comprises a matrix of 128 X 16 readout cells of 50 mu m X 500 mu m and peripheral functions with 4 distinct modes of initialization and operation, together more than 800 000 transistors. Each cell contains a complete chain of amplifier, discriminator with adjustable threshold and fast-OR output, a globally adjustable delay with local fine-tuning, coincidence logic and memory. Every cell can be individually addressed for electrical test and masking, First results have been obtained from electrical tests of a chip without detector as well as from source measurements, The electronic noise without detector is similar to 100 e(-) rms. The lowest threshold setting is close to 2000 e(-) and non-uniformity has been measured to be better than 450 e(-) rms at 5000 e(-) threshold. A timewalk of < 10 ns and a precision of < 6 ns rms on a delay of 2 mu s have been measured. The results may be improved by further optimization

    LHCb calorimeters: Technical Design Report

    Get PDF

    LHCb RICH: Technical Design Report